CF1R, CF2R, CF3R: who signs what, and when

Three residential compliance certificates, one per phase of the job — Certificate of Compliance, Certificate of Installation, Certificate of Verification. Here is who signs each one, and in what order they happen.

The three certificates

One job, three certificates, three signers

California’s residential energy code produces three compliance certificates, and they are not versions of the same document. The CF1R is the Certificate of Compliance, the CF2R is the Certificate of Installation, and the CF3R is the Certificate of Verification — one per phase of the job, each signed by a different person.

The short answer: the designer signs the CF1R before the permit is issued, the installing contractor signs the CF2R during construction, and an independent field rater signs the CF3R after the work is in and tested. They happen in that order, and the paperwork enforces the order.

One structural detail is worth knowing up front. All three carry two signature lines. A documentation author signs to certify the paperwork is accurate and complete. A responsible person signs to accept legal responsibility for the work the certificate covers. What changes from form to form is who that responsible person is.

CF1R — Certificate of Compliance, signed at design

The CF1R is the design-phase certificate. It goes in with the permit application, and the agency must approve it by stamp or authorized signature before the permit issues — the step that stalls projects at plan check. Its responsible person is the building designer, who may prepare the energy analysis and certificate personally or delegate that to a documentation author whose signature, the compliance manual is explicit, certifies the documentation only — not the design features. That is the arrangement here: I am the documentation author, you stay the responsible designer.

Where registration is required, both sign electronically in an approved registry first, and only a registered copy showing the assigned registration number is accepted at plan check. For the form itself, see what is a CF1R; for the wider set, the Title 24 forms page.

CF2R — Certificate of Installation, signed by the installer

The CF2R belongs to construction, completed by the contractors who install the regulated features — windows, ducts and HVAC equipment, ventilation, envelope-tightness measures, lighting, insulation. Its declaration is that the installation conforms to all applicable codes and regulations and to the plans and specifications the enforcement agency approved. The responsible person is whoever is in charge of that installation and eligible under Division 3 of the Business and Professions Code for that scope; several trades each sign their own portion.

A builder or general contractor may sign for subcontractors they hire, but preparation and signature responsibility still reside with the specialty subcontractor who installed. The signed CF2R is posted at the job site for review at final inspection, and a copy goes to the homeowner. I do not prepare or sign CF2R forms.

CF3R — Certificate of Verification, signed by the rater

Where compliance requires field verification, a certified rater conducts the testing, then completes, signs and submits the CF3R as responsible person. On 2025-code permits — applications submitted on or after January 1, 2026 — that is an ECC-Rater under the Energy Code Compliance program. On 2019 and 2022-cycle permits the same section reads identically with HERS Rater and HERS field verification instead — the certificate did not change, the program was renamed. See HERS and ECC field verification and the 2025 code changes.

The rater is a third party, independent from the builder or general contractor, and under the 2025 code that independence sits in the administrative code rather than in custom. ECC-Providers, ECC-Raters and ECC-Rater companies may not hold a financial interest in the builder, designer or subcontractor signing as responsible person — with one declared exception, for a rater company that files a separation-of-services declaration with its provider. The roles do not collapse into each other either. An ECC-Rater is not eligible to sign the CF1R as responsible designer. A rater company may be named document author on a CF1R or a CF2R, but it cannot sign either one as responsible person, and it can sign a CF2R only as an authorized representative under a written delegation of signature authority that is also on file with the provider — the installer stays legally responsible either way.

A CF3R records a result, not just a signature: each test is reported to the registry as pass or fail. On a pass the registry issues a registered copy. On a fail the failure goes into the registry even if the installer corrects it immediately, and the work is retested.

The sequence, and why it cannot be shuffled

The CF1R is where a project learns which measures need field verification later, and arranging a rater is then the builder’s job. When installation is finished, the responsible person completes the CF2Rs. Only after the CF1R and required CF2Rs are registered does the rater verify: no CF3R may be signed for a house lacking a registered CF2R signed by the installer, the one exception being sample-group homes. All three go through the same registry, and no certificate of occupancy issues until the agency has all of them.

Not every project produces all three

A CF3R exists only where compliance requires field verification, and that requirement is also what drives registration for the whole set — which the compliance manual frames as all newly constructed homes, most additions, and many alterations. Projects with no field-verified measures run a non-registered prescriptive path instead: dedicated CF1R and CF2R forms exist for those additions and alterations, with no CF3R at all. There is one documented exception to CF1R-before-permit — to simplify the permit process for HVAC changeouts, Section 10-103 allows the registered CF1R-ALT-02-E to be submitted at final inspection rather than before the permit is obtained.

Where verification applies, the forms pair one to one. Duct leakage is a CF2R-MCH-20-H from the installer and a CF3R-MCH-20-H from the rater; refrigerant charge is CF2R-MCH-25-H and CF3R-MCH-25-H. Space-conditioning airflow rate and fan efficacy, quality insulation installation, whole-building air leakage and mechanical-ventilation verification generally come up as well — examples, not a complete list.

These three letters are the single-family set

The CF1R family covers single-family dwellings of any number of stories, including accessory dwelling units and townhouses, plus duplexes. Three-or-more-unit low-rise multifamily uses LMCC, LMCI and LMCV. Nonresidential, hotel/motel and high-rise multifamily work uses NRCC for compliance, NRCI for installation and NRCV for verification, plus the NRCA acceptance certificates — the forms on a tenant improvement. The Title 24 glossary collects the rest.

Where I fit in the three

I build the energy model and prepare the CF1R as documentation author, then register it through CHEERS, a CEC-approved ECC-Provider. You sign as responsible designer. The CF2R is the installer’s and the CF3R is the rater’s — I prepare neither, and that is the right division of the work. What I do is flag, off the CF1R, which measures need field verification, so the rater is no surprise at final inspection.

Rates

Prices

Flat fees, in writing before I start. No hourly, no bid package, no change-order games — the number on the quote is the number on the invoice.

New client offer

Your first report with me

$150$9924–48 hours

One per client, homes under 3,000 square feet. Full energy model, CF1R and CHEERS registration. It’s a test run — send one job and see how it goes.

Every model after the first

$150Per model

The standard rate once you’re a client — the second building, ADU plus main house, the next project that walks in. Back in 3 business days.

Over 3,000 square feet

QUOTED

Quoted from the plans before any work starts, same day.

24×36 plan-sheet set

$20

Your CF1R laid out full size, matched to your drawing set. Comes back as a PDF you drop straight in.

Revisions

FREEFirst two

Two revisions included, plus questions any time. Past two I quote first, before I touch it.

Commercial / tenant improvement

QUOTEDSame day

Send the plans and you’ll have a flat quote back the same day. No deposit, no minimum.

Disclosure

One honest note

I’m not a licensed engineer or architect, and I don’t stamp drawings. On the CF1R I’m the documentation author — you stay the responsible designer. Nothing about your role on the job changes.

That’s on purpose. I’m not after your scope or your clients. I do one piece of the permit set — the piece that usually holds it up — and I do it fast.

Questions

CF1R, CF2R and CF3R questions

If yours isn’t here, see the full FAQ or call and ask.

What is the difference between a CF2R and a CF3R?

Different people, different moments. The CF2R is the Certificate of Installation, completed and signed by the contractor who installed the regulated energy feature, declaring that the installation conforms to the approved plans and specifications. The CF3R is the Certificate of Verification, completed and signed by an independent field rater who tested that feature and reported a pass or a fail to the registry.

On field-verified measures the two forms pair one to one — duct leakage is a CF2R-MCH-20-H from the installer and a CF3R-MCH-20-H from the rater. The installer’s form comes first: a rater may not sign a CF3R for a house with no registered CF2R signed by the installer, the one exception being homes in a sample group.

What is a CF2R, and who fills it out?

The Certificate of Installation. It is completed during construction by the contractors who install the regulated energy features — windows, the ducts and HVAC equipment, ventilation, the measures affecting envelope tightness, lighting, insulation — and it declares that the installation conforms to all applicable codes and regulations and to the plans and specifications the enforcement agency approved.

The responsible person is whoever is in charge of that installation and eligible under Division 3 of the Business and Professions Code for that scope of work. A general contractor may sign on behalf of subcontractors they hire, but preparation and signature responsibility still reside with the specialty subcontractor who did the installing. A signed copy is posted at the job site for the enforcement agency to review at final inspection, and a copy goes to the homeowner.

What is a CF3R, and does every project need one?

The Certificate of Verification, completed and signed by a certified field rater — an ECC-Rater on 2025-code permits, a HERS Rater on 2019 and 2022-cycle permits. Not every project requires one. It applies where compliance depends on measures that have to be verified in the field, and the CF1R itself lists which measures those are.

Whether a CF3R is required is also what drives registration for the whole document set. The compliance manual frames that as required for all newly constructed homes, most additions, and many alterations. More on the testing itself is on the HERS and ECC verification page.

Do you prepare the CF2R and CF3R too?

No. I prepare the CF1R as documentation author and register it through CHEERS; you sign as responsible designer. The CF2R is the installing contractor’s certificate, signed on their license and about their own work. The CF3R belongs to an independent field rater — one who, under the 2025 code, may not hold a financial interest in the builder, designer or subcontractor signing as responsible person on the project, apart from a declared separation-of-services exception available to rater companies.

What I do is flag, off the CF1R, which measures are headed for field verification, so lining up a rater is not a surprise at final inspection.

Is the CF1R always registered before the permit is issued?

The Certificate of Compliance is submitted with the permit application and has to be approved by the enforcement agency, by stamp or authorized signature, before the permit is issued. Registration is a separate question: it is triggered by the project requiring field verification and diagnostic testing, and non-registered prescriptive CF1R forms exist for additions and alterations that do not. Where registration does apply, only a registered copy showing the registration number is accepted at plan check.

There is one documented exception to the timing. To simplify the permit process for HVAC changeouts, Section 10-103 allows the registered CF1R-ALT-02-E to be submitted at final inspection rather than before the permit is obtained.

Why do some forms say HERS and others say ECC?

The program was renamed for the 2025 code cycle, which applies to permit applications submitted on or after January 1, 2026. What was HERS field verification by a certified HERS Rater is Energy Code Compliance verification by a certified ECC-Rater under the 2025 code. The code section reads the same way on either side of the change — the certificate structure did not change, the naming did.

Permits still running on the 2019 or 2022 cycle keep the HERS naming. See the 2025 code changes for the rest of the transition.

Start the set with the CF1R

Send the plan set and the CF1R comes back registered, with you named as responsible designer and the field-verification measures flagged.